Search:
A & D Moisture Analyzers
Moisture Analyzers
Fast and uniform heating with halogen lamp and innovative SRA technology
Straight halogen lamp and uniquely designed SRA (Secondary Radiation Assist) filter gives shorter measurement time, thanks to fast and uniform heating
High repeatability
With SHS (Super Hybrid Sensor) featured as the weight sensor, ultra accurate moisture content determination is possible based on high precision weighing of even a small sample
High moisture content measurement
MS measures the moisture content at 0.001 to 1% resolution suitable for low moisture content samples as well as Karl Fischer method, yet requires no special knowledge or training and produces no harmful waste
Standard WinCT-Moisture ( for MS & MX) for real-time graph displaying
WinCT-Moisture is an original software application designed to display a graph of moisture content rate change while measuring with a connected PC
Sodium Tartrate Dihydrate comes as standard for accuracy checking
Sodium Tartrate Dihydrate is a chemical material that has stable moisture content of 15.66% (+0.3/-0.1), and thus is best to use for accuracy check to maintain the reference value of the analyzer
Calibration of the heater temperature ( for MS & MX)
With the temperature calibrator (optional), calibration result can be output in the format that conforms to GLP, GMP, ISO
View Brochure PDF
Straight halogen lamp and uniquely designed SRA (Secondary Radiation Assist) filter gives shorter measurement time, thanks to fast and uniform heating
High repeatability
With SHS (Super Hybrid Sensor) featured as the weight sensor, ultra accurate moisture content determination is possible based on high precision weighing of even a small sample
High moisture content measurement
MS measures the moisture content at 0.001 to 1% resolution suitable for low moisture content samples as well as Karl Fischer method, yet requires no special knowledge or training and produces no harmful waste
Standard WinCT-Moisture ( for MS & MX) for real-time graph displaying
WinCT-Moisture is an original software application designed to display a graph of moisture content rate change while measuring with a connected PC
Sodium Tartrate Dihydrate comes as standard for accuracy checking
Sodium Tartrate Dihydrate is a chemical material that has stable moisture content of 15.66% (+0.3/-0.1), and thus is best to use for accuracy check to maintain the reference value of the analyzer
Calibration of the heater temperature ( for MS & MX)
With the temperature calibrator (optional), calibration result can be output in the format that conforms to GLP, GMP, ISO
View Brochure PDF
Unit of Measure
Items |
/Asset/A-D-MF-MX-ML-MS-Moisture-Analyzer-photo.jpg MS-70 A & D MS-70 Moisture Analyzer |
/Asset/A-D-MF-MX-ML-MS-Moisture-Analyzer-photo.jpg MX-50 A & D MX-50 Moisture Analyzer |
/Asset/A-D-MF-MX-ML-MS-Moisture-Analyzer-photo.jpg MF-50 A & D MF-50 Moisture Analyzer |
/Asset/A-D-MF-MX-ML-MS-Moisture-Analyzer-photo.jpg ML-50 A & D ML-50 Moisture Analyzer |
||||
Weighing Capacity | N/A 71 g | N/A 51 g | N/A 51 g | N/A 51 g | ||||
Readability | N/A 0.0001 g at 0.001% - 0.1% | N/A 0.001 g at 0.01% | N/A 0.002 g at 0.05% | N/A 0.005 g at 0.1% | ||||
Pan Size (Dia.) | N/A 2.16 in85 mm | |||||||
Measurement Method | N/A 400 W straight halogen lamp heating system with SRA filter and SHS weighing technology | |||||||
Moisture Content Display | N/A 0.001 %0.01 %0.1 % | N/A 0.01 %0.1 % | N/A 0.05 %0.1 %1 % | N/A 0.1 %1 % | ||||
Moisture Content Accuracy over 1 g (Standard Deviation) | N/A 0.05 % | N/A 0.1 % | N/A 0.20 % | N/A 0.5 % | ||||
Moisture Content Accuracy over 5 g (Standard Deviation) | N/A 0.01 % | N/A 0.02 % | N/A 0.05 % | N/A 0.1 % | ||||
Heating Technology | N/A Halogen lamp (Straight type, 400 Watt max, 5000 hours) | |||||||
Drying Temperature (1ºC Increment) | N/A 30 to 200 ºC86 to 392 ºF | |||||||
Memory of Measurement Programs | N/A 20 sets | N/A 20 sets | N/A 10 sets | N/A 5 sets | ||||
Measurement Programs | N/A Automatic Mode Manual Mode Quick Mode Standard Mode Timer Mode | |||||||
Measurement Mode | N/A Dry content Moisture content (Wet or Dry base) Ratio Weight | |||||||
Heating Mode | N/A Standard Quick Ramp Step | N/A Standard Quick Ramp Step | N/A Standard Quick Ramp Step | N/A Standard Quick | ||||
Display Type | N/A Large VFD | |||||||
Interface | N/A RS-232C Standard | |||||||
Data Memory Function | N/A 100 | N/A 100 | N/A 50 | N/A 30 | ||||
Operating Temperature Range | N/A 5 - 40ºC/41 - 104ºF, less than 85% RH | |||||||
Calibration | N/A GLP GMP ISO | |||||||
Self Check Function | N/A Standard | |||||||
Communication Software | N/A WinCT-Moisture Standard | N/A WinCT-Moisture Standard | N/A WinCT Standard | N/A | ||||
Power Requirement | N/A AC 100 V to 120 V (3A) or AC 200 V to 240 V (1.5A), 50/60 Hz, Approx. 400 W | |||||||
Scale Width | N/A 8.46 in215 mm | |||||||
Scale Depth | N/A 12.60 in320 mm | |||||||
Scale Height | N/A 6.81 in173 mm | |||||||
Shipping Weight | N/A 6 kg13.2 lbs | |||||||
|